A decibel (dB) is a logarithmic unit that expresses the ratio between two values of the same quantity, such as two powers, two voltages or two sound pressures. One decibel is a tenth of a bel. On its own, a decibel value says how much bigger or smaller one thing is than another; it becomes an absolute level only when a suffix names the reference, as in dB SPL, dBu, dBV or dBFS.
Audio runs on decibels because the numbers involved are enormous and hearing works roughly in ratios. The quietest sound a healthy ear can detect and the loudest it can tolerate differ in sound pressure by a factor of about a million, and in power by about a million million. The decibel turns that range into a scale from 0 to roughly 120 or 130, turns multiplication into addition, and lets an engineer say “3 dB more” instead of “1.995 times the power.” Every fader, meter, compressor and spec sheet in a studio speaks this language.
Table of Contents
What is a decibel?
The decibel is a ratio, not a unit of loudness. Saying a signal is “10 dB” makes no more sense than saying a price is “10 percent”: ten percent of what? The answer is always a reference. When the reference is the previous level, the decibel describes a change (“turn it up 3 dB”). When the reference is a fixed, agreed value, the decibel describes an absolute level (“the vocal peaks at -6 dBFS,” “the room sits at 82 dB SPL”).
Because the unit is logarithmic, equal steps in decibels are equal ratios. Going from 60 to 70 dB is the same tenfold power increase as going from 90 to 100 dB. That’s also roughly how hearing behaves: the ear judges changes in level proportionally, so a logarithmic scale lines up with perception far better than a linear one. The match isn’t perfect (perceived loudness depends on frequency and level too), but it’s close enough to have made the decibel universal.
The unit is written dB: lowercase d for deci, capital B for Bell. In casual writing you’ll see “db,” “DB” and “Db,” but the official symbol keeps the capital B in honor of Alexander Graham Bell.
A short history: from telephone wire to mixing desk
The decibel was born in the telephone industry. Early telephone engineers measured signal loss in “miles of standard cable” (MSC), the attenuation of one mile of a reference cable with defined resistance and capacitance per mile. The unit was clumsy because the loss of real cable varies with frequency, so the Bell System replaced it with a purely mathematical unit.
In July 1924, W. H. Martin of the Bell System described the new transmission unit (TU) in the Bell System Technical Journal. The TU was defined as ten times the base-10 logarithm of a power ratio and was chosen to be close to the old unit: 1 TU equals about 1.056 MSC. In 1928 the Bell System renamed the TU the decibel, a tenth of a new unit called the bel, named after Alexander Graham Bell. Martin explained the change in “Decibel – The Name for the Transmission Unit,” published in the Bell System Technical Journal in January 1929. Europe also adopted the neper, based on the natural logarithm and named after John Napier, the inventor of logarithms; the neper survives in some physics and telecom work, while audio settled on the decibel.
From telephony the decibel moved into broadcasting. In 1938–39, engineers from CBS, NBC and Bell Labs agreed on a standard volume indicator, the VU meter, whose 0 VU mark corresponds to +4 dB above 1 milliwatt in a 600-ohm line. That reference is the ancestor of the +4 dBu “pro” line level still printed on studio gear today. Digital recording added dBFS in the late 1970s and 1980s, and loudness metering added LUFS in the 2000s. The underlying math hasn’t changed since 1924.
The math: 10 log and 20 log
There are two decibel formulas, and confusing them is the single most common decibel mistake. Which one applies depends on whether the quantity is a power or a root-power (also called a field quantity) such as voltage, current or sound pressure.
Power ratios: 10 log
For powers (watts of amplifier output, acoustic intensity, energy), the level difference in decibels is:
L = 10 × log₁₀(P₁ / P₀)
Double the power and the level rises by 10 × log₁₀(2) ≈ 3.01 dB. Multiply it by 10 and the level rises by exactly 10 dB; by 100, 20 dB; by 1,000, 30 dB.
Voltage and pressure ratios: 20 log
Power is proportional to the square of voltage (P = V²/R) and to the square of sound pressure. Squaring inside a logarithm becomes a factor of 2 outside it, so for voltages and pressures the formula becomes:
L = 20 × log₁₀(V₁ / V₀)
Double the voltage and the level rises by 20 × log₁₀(2) ≈ 6.02 dB. Multiply it by 10 and the level rises by 20 dB. The two formulas agree with each other: doubling the voltage across the same resistance quadruples the power, and 10 × log₁₀(4) is also 6.02 dB. In practice, almost everything you touch in a studio (fader positions, meter readings, preamp gain, mic sensitivity, dBu, dBFS) is a 20 log quantity.
Quick reference
| Level change | Voltage or pressure ratio | Power ratio | Where you meet it |
|---|---|---|---|
| +1 dB | 1.122× | 1.259× | Roughly the smallest level change many listeners can reliably notice on music |
| +3 dB | 1.413× | 1.995× (double) | Doubling power; summing two uncorrelated signals of equal level |
| +6 dB | 1.995× (double) | 3.98× | Doubling voltage; summing two identical, in-phase signals |
| +10 dB | 3.162× | 10× | Often perceived as roughly “twice as loud” |
| +20 dB | 10× | 100× | A big gain step; the same 20 dB as a typical mic pad, in reverse |
| +40 dB | 100× | 10,000× | Typical preamp gain for a condenser on a quiet source |
| +60 dB | 1,000× | 1,000,000× | Typical preamp gain for a low-output dynamic on speech |
| -6 dB | 0.5× | 0.25× | Halving the voltage; doubling the distance from a point source |
Negative decibels are just ratios below 1. Cutting 6 dB halves the voltage; cutting 20 dB leaves one tenth. A decibel value of 0 means the two quantities are equal, which is why a fader at 0 dB is called unity gain: it neither boosts nor cuts.
Working it out without a calculator
Engineers rarely touch a logarithm in a session. They chain a handful of anchors. Because decibels add when ratios multiply, +26 dB is +20 dB (×10 voltage) plus +6 dB (×2), so ×20 in voltage. A 1,000× voltage gain is 3 × 20 dB = 60 dB. Halving the voltage three times is -18 dB, so a signal at -18 dBFS has one eighth of the full-scale amplitude. With 3, 6, 10 and 20 memorized, most studio arithmetic takes seconds.
Adding decibels: why 80 dB plus 80 dB isn’t 160 dB
Decibels don’t add like ordinary numbers when you combine signals, because you have to go back to the underlying quantities, add those, and convert again. The result depends on how the signals relate to each other.
- Uncorrelated signals (two different instruments, two separate guitar takes, two noise sources) add in power. Two equal-level uncorrelated sources give +3 dB: two 80 dB SPL sources make about 83 dB SPL, not 160.
- Correlated, in-phase signals (the same vocal on two channels, a mono source panned center into a summing bus) add in voltage. Two identical signals give +6 dB.
- Correlated, opposite-polarity signals cancel. Two identical signals with one inverted add to nothing, which is the principle behind phase cancellation problems and also behind balanced lines.
The same logic scales up. Summing 16 equal-level uncorrelated tracks raises the total by 10 × log₁₀(16) ≈ 12 dB; summing 32 raises it by about 15 dB. That’s one reason a mix bus fills up faster than beginners expect, and why gain staging leaves room before the sum.
When two levels differ a lot, the smaller one barely matters. A source 10 dB quieter than another adds only about 0.4 dB to the total. That’s useful in practice: if a noise source sits 20 dB below the music, removing it won’t change the measured level, though you may still hear it.
Reference levels: dB SPL, dBu, dBV, dBFS and friends
A suffix after “dB” fixes the reference and turns a ratio into an absolute level. These are the ones you meet in audio.
| Unit | Reference (0 dB = …) | What it measures | Where you see it |
|---|---|---|---|
| dB SPL | 20 µPa sound pressure | Acoustic sound pressure | Sound level meters, mic max SPL specs, hearing safety |
| dB(A), dB(C) | 20 µPa, with A or C frequency weighting | Weighted sound pressure | Noise regulations (A), loud music and calibration (C) |
| dBu | 0.775 V RMS | Voltage, regardless of load | Pro analog gear: +4 dBu line level, max output specs |
| dBV | 1 V RMS | Voltage | Consumer gear (-10 dBV), mic sensitivity in dBV/Pa |
| dBm | 1 mW (traditionally into 600 Ω) | Power | Telephone, broadcast and RF; vintage specs |
| dBFS | Digital full scale | Digital level | DAW meters, converters, plugins |
| dBTP | Digital full scale, true (reconstructed) peak | Inter-sample peak level | Mastering limiters, delivery specs |
| LUFS / LKFS | Digital full scale, K-weighted and gated | Program loudness | Streaming, broadcast loudness targets |
Each has its own entry with the full story: dBu (with dBV and dBm), dBFS, A-weighting and loudness. The key point here is that the numbers aren’t interchangeable. A +4 dBu signal is about +1.78 dBV, and how many dBFS it becomes depends entirely on how the converter is calibrated.
dB SPL
Sound pressure level uses 20 micropascals as its reference, close to the threshold of hearing at 1 kHz for a young, healthy listener. Because pressure is a root-power quantity, dB SPL uses the 20 log formula. One pascal, a figure you’ll see in every microphone datasheet, is about 94 dB SPL, which is why mic sensitivity is quoted at 94 dB SPL.
| Situation | Approximate level |
|---|---|
| Threshold of hearing at 1 kHz | 0 dB SPL |
| Quiet recording studio, background | 20–30 dB(A) |
| Normal conversation at 1 m | around 60 dB SPL |
| Typical mix-room monitoring | roughly 75–85 dB SPL (C-weighted) |
| Loud rock concert near the PA | 100–110+ dB SPL |
| Snare drum, a few centimeters from the head | can exceed 130 dB SPL |
These are typical values, not standards; real situations vary a lot. Note also that 0 dB SPL is not silence. It’s the reference pressure, and quieter sounds simply have negative levels.
Decibels and hearing
A few rules of thumb connect the numbers to what you hear. They’re approximations, and the ear’s sensitivity depends on frequency and level (see equal-loudness contours), but they’re the working knowledge of every engineer.
- About 1 dB is roughly the smallest level difference many people can reliably detect on program material in a careful comparison. Smaller differences still matter: a 0.5 dB louder version of a mix often just sounds “better,” which is why level-matched comparisons are essential.
- About 3 dB is clearly noticeable but modest, even though it doubles the power.
- About 10 dB is often perceived as roughly twice as loud, even though it’s ten times the power. That’s why a 100-watt amplifier isn’t dramatically louder than a 50-watt one: doubling the power buys only 3 dB.
Exposure and hearing safety
Hearing damage depends on level and time. US regulations show the two ways of trading one against the other. The OSHA occupational limit is 90 dBA for eight hours with a 5 dB exchange rate (time halves for every 5 dB), with a hearing-conservation action level at 85 dBA. The NIOSH recommended limit is stricter: 85 dBA for eight hours with a 3 dB exchange rate, which follows the equal-energy principle, since 3 dB is double the acoustic energy.
| Level (dBA) | OSHA permissible time (5 dB rule) | NIOSH recommended time (3 dB rule) |
|---|---|---|
| 85 | 16 hours (action level) | 8 hours |
| 88 | about 10.6 hours | 4 hours |
| 91 | about 7 hours | 2 hours |
| 94 | about 4.6 hours | 1 hour |
| 97 | about 3 hours | 30 minutes |
| 100 | 2 hours | 15 minutes |
| 105 | 1 hour | about 4.7 minutes |
| 110 | 30 minutes | about 1.5 minutes |
The table is calculated from each rule. The gap at high levels is striking: a live engineer standing in 100 dBA has two hours under the OSHA rule and fifteen minutes under the NIOSH recommendation. Many hearing professionals and audio organizations follow the more conservative 3 dB rule, and long mix sessions at high levels are one of the classic ways engineers lose the very tool they work with.
Decibels in practice
On a mixer or in a DAW
Faders are marked in decibels relative to unity. The scale isn’t linear: there’s a lot of travel between -10 and +10 dB, where fine moves happen, and very little between -40 dB and the bottom, which is effectively a fade to silence. That’s one reason good gain staging keeps faders near unity. Plugin controls such as threshold, makeup gain and EQ boosts are all in decibels too.
Preamp gain and pads
A mic preamp is specified in decibels of voltage gain: 60 dB of gain multiplies the voltage by 1,000. A typical pad of -20 dB divides the voltage by 10. Mic sensitivity, preamp gain, line level and converter calibration all chain together in decibels, so you can follow a signal from a singer’s mouth to the DAW meter by adding and subtracting.
Distance and the inverse square law
For a small source in free space, sound pressure falls by about 6 dB per doubling of distance. A guitar amp measuring 100 dB SPL at 1 m gives about 94 dB SPL at 2 m and 88 dB SPL at 4 m. Rooms, large sources and arrays change the picture (reflections stop the level from falling as fast), but the rule explains why a few centimeters matter so much with close miking, and why moving a mic back is often a better fix than a pad.
Monitoring calibration
Several calibration schemes tie digital level to acoustic level. Film mixing commonly calibrates each screen channel so that pink noise at -20 dBFS (measured on an average-responding meter) produces 85 dB SPL, C-weighted, slow response, as described in SMPTE RP 200. Mastering engineer Bob Katz’s K-System uses 83 dB SPL per speaker for pink noise at the meter’s zero mark, with meter scales K-20, K-14 and K-12 placing that zero 20, 14 or 12 dB below full scale. Neither is a law of nature, but both make level decisions repeatable.
Typical starting values
These are common conventions, not rules, and the right answer always depends on the material:
- Tracking in 24-bit: average levels roughly 18–20 dB below full scale, with peaks well clear of 0 dBFS. See dBFS.
- A level-matched A/B comparison: within about 0.5 dB, or the louder version usually wins.
- A noise floor 60 dB or more below the music is rarely a problem in a finished mix; recording chains are usually far better than that. See signal-to-noise ratio.
Common mistakes and myths
- “3 dB is twice as loud.” It’s twice the power. Perceived loudness doubles at something closer to 10 dB.
- “6 dB is always double.” Only for voltage or pressure. For power, double is 3 dB.
- “0 dB means silence.” 0 dB means “equal to the reference.” 0 dB SPL is the threshold-of-hearing reference, 0 dBFS is the loudest possible digital level, and 0 dB on a fader is unity gain.
- “A decibel is a unit of volume.” It’s a ratio. Without a reference it can describe a change, but not a level.
- “+4 dBu and -10 dBV are 14 dB apart.” They use different references. The real difference is about 11.8 dB. See line level.
- “Two 100 dB speakers make 200 dB.” Two uncorrelated sources of equal level add about 3 dB; perfectly correlated ones at the same point add at most 6 dB.
Decibel vs related terms
| Term | What it is | Relation to the decibel |
|---|---|---|
| Bel | Logarithmic ratio unit, log₁₀ of a power ratio | 1 bel = 10 decibels; almost never used on its own |
| Neper | Logarithmic unit based on the natural logarithm | 1 Np ≈ 8.686 dB (for field quantities); common in physics, rare in audio |
| Gain | Amplification, usually expressed in dB | A gain of 20 dB is a 10× voltage ratio; see gain |
| Attenuation | Reduction of level | Expressed as negative dB or as “x dB of attenuation” |
| Volume / loudness | Perceived strength of a sound | Related but not identical; perception depends on frequency and duration |
For more on the neighbors, see gain, attenuation, headroom and dynamic range.
Measuring decibels: meters and measurement mics
Some links in this section go to Thomann and are affiliate links: if you buy through them, musicproductionglossary.com may earn a small commission at no extra cost to you. Learn more.
To measure acoustic level you need a sound level meter or a measurement microphone with software. Sound level meters are graded by IEC 61672, with Class 1 for precision work and Class 2 for general use. For room tuning and monitor calibration, an omnidirectional measurement mic and software such as an RTA or Room EQ Wizard is the usual home-studio route. These are representative examples:
- Behringer ECM8000: a long-standing budget omnidirectional measurement mic, phantom-powered, commonly used with room measurement software. Unit-to-unit variation is the trade-off at this price.
- Superlux ECM999: another inexpensive omni measurement condenser for basic room and PA work.
- Sonarworks SoundID Reference Measurement Microphone: each unit comes with its own calibration profile, which removes much of the guesswork of cheap measurement mics.
- beyerdynamic MM 1: a sturdier omni measurement mic that beyerdynamic specifies as diffuse-field calibrated.
- NTi Audio XL2: a handheld acoustic analyzer and sound level meter that NTi specifies to IEC 61672 Class 1 or 2 (depending on the measurement mic), widely used for live sound level monitoring and acoustic work.
A phone app can give a rough idea, but phone microphones and their processing aren’t calibrated, so treat app readings as estimates, especially at high levels.
FAQ
What is a decibel in simple terms?
A decibel is a way of comparing two levels on a logarithmic scale. +3 dB means double the power, +6 dB means double the voltage or sound pressure, and +20 dB means ten times the voltage. Add a suffix such as SPL, dBu or dBFS and it becomes an absolute level.
Why are there two decibel formulas?
Power quantities use 10 × log₁₀ of the ratio. Voltage and sound pressure use 20 × log₁₀, because power is proportional to their square. Both give the same answer for the same physical change.
How many decibels is twice as loud?
Roughly 10 dB for most listeners, though it varies with frequency and level. A 3 dB increase doubles the power but sounds only moderately louder.
Is 0 dB silence?
No. It means the measured value equals the reference. 0 dB SPL is the threshold-of-hearing reference, 0 dBFS is digital full scale, and 0 dB on a fader is unity gain.
How loud is too loud?
NIOSH recommends no more than 85 dBA averaged over eight hours, halving the time for every 3 dB above that: 15 minutes at 100 dBA. OSHA’s legal limit is less strict, using 90 dBA and a 5 dB exchange rate.
How much does sound drop with distance?
For a small source in open space, about 6 dB every time the distance doubles. Indoors, reflections make the drop smaller beyond a certain distance.
What’s the difference between dB and dBFS?
dB on its own is just a ratio. dBFS is a level relative to digital full scale, the highest value a fixed-point digital system can represent, so dBFS readings in practice are 0 or negative.