ORTF stereo is a near-coincident microphone technique that uses two cardioid capsules spaced 17 cm (6.7 in) apart and aimed outward at a total angle of 110 degrees. Each microphone records one stereo channel. The spacing creates small differences in arrival time, while the cardioid angles create differences in level, so both cues contribute to where a sound appears between the loudspeakers.
The arrangement was developed in French broadcasting and remains useful for recording ensembles, choirs, acoustic instruments, and live performances. Compared with a coincident XY stereo pair, ORTF typically produces a broader sense of space because it adds deliberate microphone spacing. That benefit comes with a tradeoff: summing the channels to mono can change the tone of some sounds.
The numbers identify the technique, but they do not choose the best position in a room. Seventeen centimeters and 110 degrees describe the array; placement and aiming determine the recording. The sound of an ORTF pair also depends on the microphones’ polar patterns, their off-axis response, the acoustic environment, and how widely the performers are spread out.
Table of Contents
What makes an ORTF microphone pair different?
Three properties define conventional ORTF: two cardioid pickup patterns, 17 cm between the acoustic centers of the capsules, and 110 degrees between the microphones’ principal axes. The angle is an included angle, measured from one microphone’s forward direction to the other. With a symmetrical array, the left microphone points 55 degrees left of the center line and the right microphone points 55 degrees right.
| ORTF parameter | Conventional setup | What to check |
|---|---|---|
| Microphones | Two cardioids with similar response | Matching off-axis behavior matters as well as matching sensitivity |
| Capsule-center spacing | 17 cm (6.7 in) | Measure between capsule centers, not clip screws or the ends of microphone bodies |
| Included angle | 110° | It is the total angle between the microphone axes, not 110° per side |
| Orientation | Symmetrical about the center of the sound stage | Aim the pair’s midpoint toward the desired center |
| Signal routing | One microphone to left, one to right | Check channel identity and appropriate gain before recording |
A stereo bar with ORTF markings makes assembly easier, but the marking on a bar does not always coincide with the position of a capsule inside its housing. A clip, a shock mount, and the microphone’s length all affect the actual capsule location. Dedicated ORTF microphones can fix the geometry mechanically; two separate microphones require it to be set and checked.
Schoeps documents the conventional dimensions and the geometry of its purpose-built ORTF mounts. RØDE’s stereo-techniques guide likewise specifies two cardioid microphones 17 cm apart with their axes 110 degrees apart. These are geometric requirements, not claims that every microphone pair with roughly similar spacing will sound identical.
Why a 17 cm measurement at the capsules matters
Suppose a stereo bar’s mounting screws are 17 cm apart, but each microphone extends a different distance beyond its clip. The actual diaphragm centers might not be 17 cm apart. The result is not the same physical array, even if the stand looks symmetrical from the audience.
Find the diaphragm position from the microphone design or manufacturer’s documentation. With front-address small-diaphragm condensers, it is often near the front of the housing, but the grille tip is not a universal measurement reference. Position the two microphone capsules on the same intended horizontal baseline, then set their axes. When shock mounts hold the bodies at different heights, verify that the microphones still observe the same center of the ensemble.
ORTF is a geometry, not a microphone brand
A matched pair of small-diaphragm cardioids is a common way to build ORTF, but no special model is required. Two compatible cardioids with similar sensitivity and directionality can work. A matched pair makes consistent imaging easier; equalizing channel gain does not correct a large difference between the microphones’ off-axis frequency responses.
Using wide cardioids, supercardioids, or a different spacing may make a useful stereo array, but its recording behavior will change. It is better described as an ORTF-inspired or modified near-coincident arrangement, rather than the standard 17 cm/110° cardioid setup.
How ORTF creates a stereo image
ORTF combines interchannel level differences and interchannel time differences. A source to the left arrives at a more favorable angle to the left-facing cardioid, so that microphone usually produces a stronger signal. Because the left capsule is also physically closer to the source, the wavefront generally arrives there slightly earlier. Both differences tend to move the apparent source toward the left speaker during stereo playback.
For a source centered in front of a symmetrical pair, the two microphone axes see similar angles and the path lengths are approximately equal. The source usually appears near the center. For an ensemble stretched across the stage, different sources produce different combinations of timing and level cues. This helps create a sense of left-to-right location while capturing some of the space around the performers. DPA’s guide to stereo setups describes how near-coincident arrays combine timing and level cues.
The spacing does not create binaural recording in the strict headphone sense. ORTF does not place the microphones inside artificial ears or reproduce the full head-related filtering of a dummy-head microphone. It is primarily a two-channel stereo arrangement intended to produce a useful image over loudspeakers.
Why the image can feel more open than XY
An XY pair positions its directional capsules as close together as practical, so separation comes mainly from level differences. ORTF deliberately adds a small path-length difference between channels. This can make the room and distributed sources sound more spacious, while preserving a recognizable center and useful directional separation.
That is a tendency, not a ranking. The source’s angular width, microphone directivity, room reflections, and monitoring setup can make a well-placed XY pair more appropriate than a poorly placed ORTF pair. Moving ORTF farther from the performers also changes the direct-to-reverberant balance; geometry alone cannot make an excessively reverberant room sound close or dry.
Why ORTF is not immune to mono problems
When left and right are summed, the same sound may arrive at the two microphones at slightly different times. Combining those signals can boost some frequencies and attenuate others. This frequency-dependent effect is related to phase interactions and comb filtering and is especially relevant to sources picked up strongly by both microphones.
The delay associated with the 17 cm separation can approach half a millisecond for a wavefront traveling along the line between the capsules. Actual delays depend on the direction and distance of each sound source. There is no universal frequency below which an ORTF recording is guaranteed to be perfectly phase-coherent, and there is no guarantee that all mono sums will sound objectionable.
In practice, ORTF is often an acceptable compromise between stereo spaciousness and mono performance. Check the mono sum of the real recording, particularly when it will be used alongside close microphones or other stereo arrays. Avoid treating “better than a widely spaced pair” as the same claim as “identical in stereo and mono.”
How to set up ORTF correctly
An ORTF pair needs a stable stand, two compatible cardioids, independent recording channels, and enough clearance that the microphones and cables do not touch or rattle. A purpose-built stereo bar with reliable position markings reduces setup time. A generic bar can work if it provides enough space and rotational adjustment.
- Mount the microphones securely. Use compatible clips or shock mounts and check that the stand can support the complete assembly without sagging.
- Set the capsule centers 17 cm apart. Measure at the diaphragm locations, not at the mount points. Leave enough clearance for connectors and cable strain relief.
- Set the total included angle to 110 degrees. Both cardioid axes should face outward, 55 degrees to either side of the center line. Keep the geometry symmetrical.
- Aim the center line at the performance. The two microphones should describe the desired left and right directions around a common center, not point arbitrarily at opposite ends of the stage.
- Connect and identify the two channels. Apply the correct phantom power if the microphones require it. Verify that the left-facing microphone feeds the left track and the right-facing one feeds the right track.
- Match the recording gain. Begin with similar gains and check a centered source. Correct electrical gain mismatch without using gain adjustments to conceal serious microphone-response differences.
- Listen in stereo, then mono. Record a short passage or soundcheck. Check center placement, width, room balance, and changes when the channels are summed.
For ordinary stereo playback, the two channels are routed to their respective left and right speaker positions. If the end product is a two-channel mix, avoid changing the stereo width before first judging the original recording. For headphones, the channel separation can feel different from loudspeaker playback, so check the intended monitoring format.
Choose position before changing the array
The 17 cm/110° geometry remains fixed, but moving the complete pair is often the most effective adjustment. If the ensemble spreads too far toward the speaker extremes, moving the pair back may bring the players into a more useful angular range. If the image sounds narrow and dominated by room sound, moving the pair closer can make the performers occupy more of the captured angle.
Height changes what the microphones emphasize: a raised pair can balance instruments across a group, while a lower pair may pick up more floor reflection or favor the nearest performers. In an acoustically difficult room, moving only a short distance can change the reflections feeding each cardioid. Adjust the stand position and central aim one variable at a time, checking the sound rather than assuming that visual symmetry guarantees tonal balance.
For outdoor recording, choose appropriate wind protection without disturbing the capsule geometry. In a room or on a stage, route cables so they do not tug on the clips, and isolate the stand if floor vibration is reaching the microphones.
Where ORTF works well, and where it can struggle
ORTF is often a sensible starting point when the recording should communicate the physical width of a performance without relying on a very large microphone spacing. Its cardioid capsules favor the forward sound stage while admitting enough off-axis energy to capture the surrounding acoustic context.
Small orchestras, choirs, and ensembles. An ORTF pair can act as the principal stereo pickup when the ensemble fits the room and microphone position. The performer-to-microphone distances and stage width influence the resulting image. A choir whose far-left and far-right singers extend beyond the useful recording angle may require a different position, height, or additional microphones.
Acoustic guitar and piano. Placing the array back far enough to hear a whole instrument can produce a convincing sense of its size. At very short distances, each capsule may favor a different part of the instrument, producing an exaggerated left/right imbalance. The position is more important than rigidly assigning one microphone to a sound hole and the other to a fretboard.
Drum overheads. ORTF can give a broad picture of cymbals and the kit as a whole, but its separated capsules do not eliminate phase interaction with close snare, kick, or tom microphones. Compare the overheads against the close mics and adjust positioning or timing only with a clear monitoring goal. There is no universal rule that 17 cm prevents all snare cancellation.
Live concerts and ambient recordings. Two cardioids can provide a practical balance between a defined stage image and surrounding sound. Placement must account for audience noise, loudspeaker spill, wind, and the distance needed to cover the entire performance. ORTF can capture an attractive space, but it cannot suppress an unwanted room or isolate a single source the way a close microphone can.
In very small rooms, the first reflections can dominate the image and color each channel differently. For recordings where mono stability is the highest priority, a coincident XY or M/S arrangement may be preferable. When the goal is to capture a much larger spatial envelope, an A/B spaced pair may be worth considering, with its own phase and center-image tradeoffs.
ORTF vs. XY, NOS, DIN, and spaced pairs
ORTF belongs to the wider family of near-coincident microphone techniques, which combine physical capsule separation with angled directional patterns. The following comparison describes conventional arrangements, not a guarantee of how any particular microphone model will sound.
| Technique | Conventional microphone geometry | Main distinction from ORTF |
|---|---|---|
| ORTF | Two cardioids, 17 cm apart, 110° included angle | Combines deliberate time and level differences at a defined spacing and angle |
| XY stereo | Directional capsules as close together as practical; angle varies | Primarily level differences, often stronger control of mono-summing effects |
| NOS stereo | Typically two cardioids, 30 cm apart, 90° included angle | More physical spacing but a smaller included angle; imaging and mono behavior change |
| DIN stereo | Typically two cardioids, 20 cm apart, 90° included angle | A different near-coincident geometry, not interchangeable with ORTF |
| A/B stereo | Spaced microphones, often omnidirectional; spacing varies | More reliance on physical spacing and arrival-time differences, with different center and mono behavior |
The specific recipes for NOS and DIN are not simply alternative names for ORTF. They warrant their own explanations because spacing and angle influence each other. Likewise, near-coincident pair is a broader family term: it describes the mechanism shared by ORTF, NOS, DIN, and other arrays, not one fixed 17 cm/110° recipe.
A Blumlein pair would use crossed figure-8 microphones, normally without deliberate capsule spacing, making it a different coincident technique. A Mid-Side arrangement also uses a different pickup and decoding method. These distinctions matter more than whether two microphones happen to be mounted on the same bar.
The 110-degree microphone angle is not the recording angle
The included microphone angle describes where the microphones point. The stereo recording angle describes the angular extent of the original sound stage that maps across the reproduced stereo image under a particular localization model. Those are different quantities.
For example, Schoeps specifies a recording angle of approximately 95 degrees for its MSTC 74 ORTF stereo microphone. That does not mean the microphones point 95 degrees apart; they remain at 110 degrees. The recording-angle estimate depends on the microphone directivity, geometry, localization assumptions, and listening conditions. Another ORTF-style array or analytical method can give a different estimate.
The practical consequence is easy to hear. If a small band occupies only a narrow angle as viewed from the microphone pair, it may occupy relatively little of the playback width. If the same array is placed too close to a very wide group, the outer performers may be pushed toward the speaker edges. Keeping 110 degrees between microphones does not automatically make the stage fit between them.
Instead of chasing one universal recording-angle number, adjust the position of the entire ORTF pair to suit the performance. Schoeps provides an Image Assistant for examining theoretical localization, time/level differences, and recording angles for microphone configurations. Its models are planning tools, not substitutes for listening to a recording in the actual room.
Hardware that holds the ORTF geometry
The simplest hardware is a sturdy stand, two compatible cardioid microphones, suitable clips, and a bar with enough reach to measure the capsule spacing and set the included angle. A dedicated ORTF mount can reduce repeated measurement, especially when setups are assembled and dismantled frequently.
Schoeps offers holders designed to set the required geometry for compatible capsules. Its MSTC 74 is an integrated two-channel ORTF microphone using a matched pair of MK 4 cardioid capsules in a fixed 17 cm/110° arrangement. The unit provides a five-pin XLR output, so the recording connection must provide the correct two-channel breakout or compatible cabling. The fact that its geometry is built in does not eliminate the need for a suitable stand position, wind protection when applicable, or a mono check.
Affiliate disclosure: The following retailer link may earn Music Production Glossary a commission at no additional cost to the purchaser.
A documented integrated example is the Schoeps MSTC 74 ORTF stereo microphone at Thomann. It illustrates fixed geometry rather than a claim that the microphone is necessary for every ORTF recording.
A separate-pair setup can be more flexible and less specialized. RØDE’s Stereo Bar has guides for ORTF spacing and angle; its markings are useful when the actual capsule locations are checked against the guides. A dedicated device trades some configurational flexibility for consistent mechanical geometry, not for guaranteed acoustic superiority.
Troubleshooting an ORTF stereo recording
When the image sounds wrong, examine the signal path and the actual physical geometry before adding stereo processing. A small error in channel assignment or aim can sound like a problem with the microphone technique itself.
| Symptom | What may be happening | What to try first |
|---|---|---|
| Stereo image is lopsided | Central aim is off; microphone gain or off-axis response differs | Check the bisector, compare gains with a centered source, confirm the pair is reasonably matched |
| Width seems exaggerated and instruments sit at the edges | Pair is too close to a broad stage; the source extends beyond the useful recording angle | Move the entire array back or alter its position; do not immediately change the ORTF geometry |
| Stereo image is narrow with too much room sound | Performers occupy a small angle at the array; pair is too distant | Move closer or find a better direct-to-room balance |
| Mono sounds hollow or thinner | Delayed copies of the same source combine differently in mono | Listen to each channel, check capsule geometry, and assess the real mono sum |
| Snare or other instrument changes when close mics are added | Timing and polarity relationships between ORTF and additional microphones | Compare sources together, check polarity and placement, adjust only with a clear reference |
| Sides appear reversed | Left and right physical channels are assigned incorrectly | Trace the channels from microphone to recorder and speaker |
| Center sound is uneven in tone | Different cardioid responses, reflections, or asymmetrical aiming | Compare microphones and room positions; match response where possible |
| Handling noise or thumps appear | Stand vibration, cable tension, or microphones touching | Inspect clips, mounts, cables, and stand isolation |
Make one physical change at a time and record a short comparison. If the source is correctly centered but the room sounds wrong, changing from 110 degrees to a different angle may be less effective than moving the microphones a short distance. If mono playback is essential, audition the actual mix in mono before committing to the array.