A subcardioid polar pattern, also called wide cardioid or sometimes hypocardioid, is a gently directional microphone response between omnidirectional and cardioid. It favors sound from the front while allowing relatively substantial pickup from the sides and rear. Compared with a conventional cardioid, its rejection is weaker, but its wide front pickup and often smooth off-axis behavior can make it useful for acoustic recording, ensemble work, and situations where some room sound is desirable.
The purpose of subcardioid is not maximum isolation. It is a controlled compromise: slightly more directional emphasis than a true omni without the strong rear rejection or generally stronger proximity effect of a conventional cardioid. Different manufacturers use the terms wide cardioid, subcardioid, and hypocardioid somewhat differently, so the actual polar plot matters.
Table of Contents
Where Subcardioid Sits Between Omni and Cardioid
In the ideal polar-pattern family, an omnidirectional microphone responds equally from every direction. A cardioid favors the front and has a deep theoretical null at 180 degrees. A subcardioid introduces some front-versus-rear difference but does not drive the rear response to zero.
Viewed on a polar chart, subcardioid resembles a softly flattened or front-heavy circle rather than the pronounced heart shape associated with cardioid. The microphone retains appreciable sensitivity behind the capsule and often picks up side-arriving sound with less level reduction than a conventional cardioid. There is no ideal side or rear null comparable to the rejection zones of supercardioid, hypercardioid, or figure-8.
This explains why subcardioid is attractive for recording when the room contributes something worthwhile. A close source still dominates because it is closer, but the microphone admits reflections more readily than a tighter directional capsule. A wide-cardioid microphone therefore cannot solve a noisy room simply because it has “cardioid” in its name.
How the Wide Cardioid Pattern Works
The directional response can be understood as a combination of sound-pressure pickup and pressure-gradient pickup. A true pressure microphone is naturally omnidirectional; a pure pressure-gradient microphone naturally produces a figure-8 shape. With a relatively large pressure component and a smaller gradient component, a microphone becomes only mildly directional.
Manufacturers implement that balance through acoustic capsule design, such as rear-entry passages and acoustic resistance, or by combining capsule signals in an appropriate multi-pattern system. The specific engineering method changes with the product. A fixed wide-cardioid small-diaphragm capsule and a large multi-pattern studio microphone switched into a wide-cardioid setting should not be assumed to have identical high-frequency or low-frequency behavior.
A commonly illustrated model has more omni behavior than cardioid behavior, resulting in modest attenuation directly behind the microphone. In practice there is no single universal percentage of pressure versus gradient that defines every microphone marketed as wide cardioid. Even closely related product lines may distinguish wide cardioid from open cardioid, with open cardioid placed a little nearer conventional cardioid.
SCHOEPS provides a useful real-world example: the MK 21 is a wide-cardioid capsule, while the MK 22 is sold separately as an open-cardioid capsule. These are not interchangeable names for the same product response. The difference can affect pickup width, stereo imaging, and the amount of ambient sound reaching the recording.
Why Natural Off-Axis Sound Can Matter More Than Deep Rejection
When several microphones record an ensemble, every microphone receives some sound from instruments other than its primary target. That bleed remains part of the recording when channels are mixed together. Deeply rejecting a competing instrument is useful in some contexts, but the spectrum of the remaining bleed matters too.
A wide-cardioid microphone that attenuates side and rear sound gradually and smoothly can record a more consistent tonal balance as instruments move across its pickup region. Its greater room pickup is not automatically a defect when reflections are natural and aesthetically useful. In classical recording, for example, room energy helps convey size, distance, and ensemble relationships.
This is why a wide cardioid can be useful as a main pair or an orchestral spot microphone, particularly when a full omni gives too much room energy while a conventional cardioid feels too selective. A smoother off-axis pickup can allow the spot channel to blend with the main array without making reflections or neighboring instruments sound aggressively filtered.
No polar-pattern category guarantees completely uncolored pickup. Capsule size, housing, acoustic damping, microphone axis, and frequency all contribute to the real off-axis response. The idealized pattern name is only the start of the comparison.
Wide Cardioid and the Proximity Effect
A subcardioid contains a pressure-gradient component, so some proximity effect can occur when a source moves close. The effect is generally less pronounced than in more strongly directional first-order patterns, but the amount depends on the individual capsule and any intentional low-frequency contouring.
That compromise can be valuable on strings, acoustic guitar, piano, or voice. A source may be positioned relatively close while producing less gradient-related bass buildup than a strongly directional microphone. The resulting low end may be easier to integrate into the recording when the surrounding acoustic environment is acceptable.
Do not interpret this as permission to put any wide cardioid right against any instrument. Acoustic instruments radiate different frequencies from different places, and very short distances can overweight one local sound-producing area. Even without pronounced proximity effect, moving the microphone closer changes the direct-to-room balance, the instrument’s apparent size, and the relative importance of nearby mechanical noise.
If closeness creates too much low end, determine whether the cause is true microphone proximity effect, instrument radiation, boundary reinforcement, or room behavior. Those problems do not all respond identically to a high-pass filter.
Practical Uses for Subcardioid Microphones
Orchestral main pairs. Wide-cardioid microphones can work in spaced or near-coincident main arrangements when the room should be included but a fully omnidirectional array produces too much diffuse pickup. The useful stereo image depends on microphone spacing, angle, source width, room, and the actual response of the capsules.
Orchestral spot microphones. A wide cardioid can gently favor a soloist or instrument section while preserving an integrated acoustic relationship with the orchestra. Its moderate directivity often requires somewhat closer placement than a cardioid to achieve a comparable ratio of direct to room sound.
Piano and other large instruments. A wide cardioid may provide a cohesive picture across a broad sound-radiating area. Piano pickup varies substantially with distance, angle, lid position, and acoustic environment. The wide pattern may be useful when a narrow mic focuses too much on a small part of the instrument.
Small vocal and acoustic groups. A wider directional response can admit movement and preserve natural relationships among performers. It is useful when the group sounds balanced acoustically and the recording does not demand substantial independent separation.
Room-conscious solo recording. A subcardioid allows a single microphone to emphasize a performer while keeping some reflection character. This can sound open in a controlled room, but excessively reverberant in an untreated one.
These are application possibilities, not preset assignments. A well-positioned cardioid or omni may be better depending on the session.
When Subcardioid Is Not the Best Tool
A wide cardioid provides less rejection of unwanted directions than cardioid, supercardioid, or hypercardioid. That makes it less attractive when the room is noisy, the microphone is very far from the wanted source, or a loud competing instrument must be isolated. A small amount of directionality does not compensate for an acoustically poor recording position.
Live reinforcement introduces an additional constraint. A subcardioid does not provide a pronounced null toward a floor monitor. That can reduce available gain before feedback compared with a properly oriented cardioid in a monitor-heavy stage environment. Feedback behavior remains a system problem rather than a feature that can be predicted solely from pattern type.
Wide cardioids can also be a weak choice for pure coincident XY recording in some configurations because there may not be enough interchannel level difference to produce the desired stereo separation. SCHOEPS notes this limitation for its MK 21 and points toward Mid-Side and near-coincident arrangements as viable alternatives. Simply crossing two microphones at 90 degrees does not create an effective stereo image with every pattern.
Subcardioid vs Open Cardioid vs Cardioid
The terminology is best treated as a directional continuum, with real-world manufacturer data determining the exact distinctions.
| Pattern family | Idealized characteristic | Practical consequence |
|---|---|---|
| Omni | Very little direction-based attenuation | Captures room sound and nearby sources broadly |
| Wide cardioid / subcardioid | Gentle front preference, no deep rear null | Moderate control while retaining substantial room pickup |
| Open cardioid | More focused than many wide cardioids, less than cardioid | Intermediate degree of rejection and coverage |
| Cardioid | Stronger front preference and ideal rear null | More isolation, less pickup directly behind |
| Supercardioid | Narrower front, side-rear nulls, rear lobe | Useful when competing sounds can be aligned with rejection directions |
The names do not define a mandatory numerical tolerance range across all brands. Some manufacturers reserve “open cardioid” for a separate product category, while others provide only one wide-cardioid variant. Reading the dB contours across multiple frequencies resolves more uncertainty than choosing a name from a brochure.
Placement and Stereo Considerations
A wide cardioid often rewards slightly more distance from a source than a close, dry spot microphone, particularly when the room has useful reflections. Start by identifying the desired sound: a focused instrument, an ensemble section, or a combination of performance and acoustic space. Then decide whether the microphone’s wide pickup supports that balance.
For a spaced or near-coincident pair, adjust both spacing and microphone angle. Spacing affects arrival-time differences and stereo width; angle and directional pattern affect left-right level differences. These mechanisms coexist and influence mono compatibility. There is no universal 30 cm spacing, 90-degree angle, or “perfect wide-cardioid pair” for every ensemble.
If an instrument is being spotted within a larger multi-mic session, monitor the spot microphone along with the main pair. A spot can sound excellent in solo but create a distracting image shift or unpleasant comb filtering in the mix. Moving it slightly may produce a more natural combination than adding equalization to solve every tonal mismatch.
Mistakes to Avoid
Using wide cardioid as a synonym for cardioid. The difference in rear pickup can substantially affect isolation and room balance.
Expecting an acoustic null. A subcardioid generally has no deep ideal rear null. It reduces off-axis sound, but does not eliminate it.
Assuming zero proximity effect. The pressure-gradient contribution may be modest, but it is not necessarily absent.
Treating every manufacturer’s wide cardioid as identical. Evaluate actual polar diagrams and frequency response, particularly at frequencies where reflections or instrument harmonics are important.