A supercardioid polar pattern is a directional microphone response with a narrower main pickup region than a conventional cardioid, strong rejection from the rear-side directions, and a small but important lobe of sensitivity directly behind the microphone. It is used when controlling room sound, nearby instruments, or stage-monitor pickup is important, without relying on the highly frequency-dependent directivity of a long interference tube.
The useful detail is that a supercardioid does not reject its rear as completely as an ideal cardioid does. Its strongest rejection occurs at two angles behind and to either side, rather than at a single point straight back. The correct way to aim a supercardioid depends on where wanted and unwanted sound actually originate.
Table of Contents
What the Supercardioid Polar Pattern Looks Like
The ideal supercardioid has a large front lobe, two rear-side nulls, and a smaller rear lobe. Its front sensitivity is highest at 0 degrees. Moving a source to either side reduces the level it produces in the microphone, with strongest attenuation occurring in the rear quadrants. Moving the source farther around toward 180 degrees brings it into the rear lobe, where some pickup returns.
In common first-order mathematical models, the supercardioid nulls lie around 125 to 126 degrees on each side of the front axis. The rear lobe is around 12 dB below the main on-axis response. Those are ideal-model landmarks, not guarantees that every product has the same null angle, depth, or rear sensitivity at every frequency.
Manufacturers do not always use the exact same pattern parameters. For example, DPA’s published microphone-pattern guide illustrates supercardioid rejection at an angle around 135 degrees, while the SCHOEPS reference model uses a slightly different balance of pressure and gradient components. Always rely on the polar diagram of the particular microphone when a few degrees of orientation matter.
A supercardioid’s pickup angle is often described using the range over which its level remains within 3 dB of the on-axis response. For an idealized conventional model, that total frontal angle is roughly 115 degrees. This is not a hard wall around the performer. A source outside that angle is attenuated, not switched off.
How Supercardioid Directivity Is Produced
An ideal omnidirectional pressure response has equal directional sensitivity. An ideal bidirectional pressure-gradient response has two opposing lobes and side nulls. Combining pressure and pressure-gradient behavior in appropriate proportions produces the family of cardioid-related patterns.
In a physical single-diaphragm directional microphone, rear acoustic ports, passages, and resistive elements shape how sound reaches the diaphragm’s rear surface. Incoming sound that reaches the front and rear through different paths produces angle-dependent pressure differences. The designer adjusts the acoustic behavior to create the intended polar response over a useful frequency range.
That does not require a supercardioid to contain two separate capsules, nor does it mean all supercardioids use exactly the same rear-port design. Multi-pattern condenser microphones can synthesize patterns by electrical means, while fixed-pattern dynamic and condenser microphones can obtain their directivity through their acoustic capsule construction.
The supercardioid’s relatively strong pressure-gradient component also makes it subject to the proximity effect. Close sources can produce increased bass relative to more distant pickup. This is neither a strict fixed dB boost nor a universally desirable vocal effect, since the result depends on frequency response, distance, and microphone design.
Why the Rear Lobe Matters More Than the Name
A cardioid’s ideal rear null makes a point directly behind the microphone an attractive place for a competing sound source. A supercardioid does not share that geometry. A loudspeaker directly behind the capsule points sound into the supercardioid’s secondary lobe, even though that lobe is much less sensitive than the front.
This becomes important in live sound. If a singer holds a supercardioid microphone and a monitor wedge fires toward the microphone from directly behind, the rear pickup can reduce available gain before feedback. When the stage layout permits, a monitor can instead be placed closer to a measured rear-side null.
There is no universal “put the wedge at 125 degrees” instruction that works for all microphones, stages, and frequencies. The actual acoustic path includes reflections, loudspeaker directivity, microphone tilt, performer movement, and frequency-dependent nulls. The polar plot gives a starting direction for a soundcheck, not a promise of immunity to feedback.
Likewise, the strongest rejection point is not necessarily the angle that sounds best when leakage is present. An unwanted instrument may be reduced greatly in level but emerge with an uneven spectrum. When the spill will remain audible in a multi-microphone mix, off-axis response can be as important as the depth of the null.
Supercardioid vs Cardioid
A cardioid is usually the simpler default for a singer or a single directional microphone in a room. Its broad front lobe makes aiming relatively forgiving, and its rear rejection is useful when competing sounds are directly behind the microphone.
A supercardioid places somewhat more emphasis on sound near the front axis while attenuating more of the lateral sound. That may reduce unwanted instrument pickup or room contribution when orientation is carefully chosen. The price is the rear lobe and a smaller zone where the wanted source remains at approximately the same level.
Imagine recording one player of a small ensemble. With a cardioid, the microphone may pick up more sound from a musician positioned well to the side, but the target performer can move a little without a sharp change in output. A supercardioid may improve separation, yet shifting the player’s position off the main axis can change both level and tone. Neither pattern automatically wins. The better choice depends on the geometry of the session and the quality of the off-axis sound.
Supercardioid vs Hypercardioid
Supercardioid and hypercardioid are related but not interchangeable patterns. A hypercardioid is generally modeled with a greater pressure-gradient contribution, which makes its main frontal region somewhat narrower and gives it a more substantial rear lobe.
| Ideal-model feature | Cardioid | Supercardioid | Hypercardioid |
|---|---|---|---|
| Primary rear-side rejection | Rear at 180° | Around 125-126° | Around 109-110° |
| Rear lobe at 180° | Ideal null | Approximately -12 dB | Approximately -6 dB |
| Approximate total frontal -3 dB angle | 131° | 115° | 105° |
| Practical trade-off | Forgiving front and strong rear rejection | Narrower front and comparatively modest rear lobe | Stronger diffuse-field directivity with more rear pickup |
These figures refer to defined theoretical first-order shapes. They do not replace measured curves from actual microphones. Different manufacturers may call patterns by the same name while producing slightly different angles or frequency responses.
One distinction is worth keeping straight: the theoretical hypercardioid maximizes the first-order directivity factor in a diffuse field, while a familiar ideal supercardioid formulation has favorable behavior for rear-hemisphere suppression. The pattern that is numerically more directional is not necessarily better for feedback control at a given loudspeaker position.
Indoor Dialogue and Other Recording Uses
A well-designed supercardioid small-diaphragm microphone is frequently useful for speech and dialogue, including indoor scenes. Compared with an interference-tube shotgun, a supercardioid capsule can provide smoother frequency-dependent side pickup in a reflective room. That can keep off-axis reflections from sounding excessively colored or hollow.
This is a tendency with a physical explanation, not a rule that shotguns always fail indoors. A short shotgun may still be appropriate, and the exact microphone, room, desired framing, and boom position determine the result. The acoustical advantage of the supercardioid becomes particularly relevant when speech moves slightly off-axis or reverberant energy arrives from many directions.
Other practical uses include instrumental spot microphones, stage vocals, speech reinforcement, percussion, and recording situations where the orientation and position of interfering sounds are well controlled. A supercardioid can be helpful for drum applications when its null directions can be aligned with prominent bleed sources, but it does not isolate a snare from a hi-hat merely because the word supercardioid appears on the box.
Getting the Placement Right
- Aim at the wanted source. Determine the capsule’s actual front axis, which may not be obvious from the microphone body alone.
- Locate the competing sound. Is it a wedge, a drum, a loudspeaker, a neighboring singer, or a reflection coming from a hard wall?
- Compare that angle with the measured nulls. Use the correct manufacturer’s polar chart, not an assumed universal template.
- Move the microphone as well as rotate it. Small reductions in source distance can improve the wanted-to-unwanted ratio more effectively than a search for a perfect null.
- Listen to the tonal balance of the leakage. A quieter but badly colored cymbal spill can still become troublesome once other microphone channels are combined.
- Test at the actual working level. On stage, feedback risk cannot be established safely from geometry alone. Frequency-specific system gain and monitor coverage matter.
For a handheld microphone, technique makes the model more complicated. A singer may rotate the microphone, cover rear vents, or change the effective distance throughout a performance. Blocking ports or gripping the capsule housing can change the designed polar response and compromise feedback resistance. Maintaining a consistent grip below the capsule is generally safer than treating the microphone grille as a handle.
Three Common Misunderstandings
“A supercardioid is deaf behind the capsule.” The ideal pattern has a rear lobe. Its deepest rejection lies off to the rear sides.
“Narrower automatically means more isolation.” Isolation depends on which directions contain competing sound and on their frequencies. The larger rear lobe of a still narrower hypercardioid may be a disadvantage in a particular setup.
“One polar chart describes all frequencies.” Real capsules have frequency-dependent behavior. A manufacturer’s multi-frequency plot is more useful when placing a monitor or evaluating tonal changes from source movement.